Grounding Pads
Neutral Electrodes
Hydrogel Technology
Strrong, but gentle hydrogel adhesive provides immediate and steady impedance upon skin contact.
Skin Compatibility
Gel and adhesive foam are tolerated even by sensitive skin. Nor residue is left on skin after application.
Reduced Edge Effect
No heavily concentrated areas of current, reducing the chance of patient burns
Adhesive Foam Border
Highly flexible adhesive foam border nad conductive gel ensures pad will stay secure.
TWINSAFE GROUNDING PADS
(Diathermy Pads / Neutral Electrodes)
The revolutionary "sling design" of the TWIN-SAFE makes it possible for the first time to use efficiently the symmetry surveillance of last-generation devices fully and completely and with arbitrary electrode orientation. The typical symmetry deviation of the HF current is below 5 % with any orientation of the TWIN-SAFE.
SWAROPLATE Split Grounding Pads
(Diathermy Pads / Neutral Electrodes)
These electrodes are for applications with HF - surgery devices which support a Contact Quality Monitoring (CQM)
SWAROPLATE Non-Split Grounding Pads
(Diathermy Pads / Neutral Electrodes)
These electrodes are for standard applications with HF - surgery devices which have no Contact Quality Monitoring (CQM).
OVALPLATE Split Grounding Pads
(Diathermy Pads / Neutral Electrodes)
OvalPlate diathermy pads can be applied in any direction due to the oval design.
OVALPLATE Non-Split Grounding Pads
(Diathermy Pads / Neutral Electrodes)
OvalPlate diathermy pads can be applied in any direction due to the oval design.
SWAROPLATE Pre-Wired Grounding Pads
(Diathermy Pads / Neutral Electrodes)
Pre-attached grounding pads are pre connected with a cable for the connection between the HF Surgery Device and the neutral electrode. Simply select the right type of cable for your device for instant application.
The advantages of SWAROPLATE Diathermy Pads / Neutral Electrodes:
- Stays in place - The adhesiveness of the foam border and of the conductive gel make sure that the electrode will not come off. This means that there is practically no danger of burnings with SWAROPLATE
- Ready to be used - Just remove the protective sheeting and apply the electrode on the prepared skin. There is no additional gel required!
- Highly flexible with excellent skin compatibility - Gel and adhesive foam are tolerated even by a sensitive skin. There is no gel left on the skin after the application
SWAROPLATE Diathermy Pads / Neutral Electrodes
- A list of compatible HF-surgery devices is available.
- Meets the requirements of IEC 60601-2-2:2009.
- For correctly applied electrodes the maximum temperature rise under standard load according IEC 60601-2-2 is typically < 4°C. Limit according to the standard is < 6°C.
- NE contact-impedance is typically 1 Ohm (for adult size electrodes).
- Shelf life is 24 months in the originally sealed bag.
Grounding Pads - English
From our patented TwinSafe design to our standard SwaroPlate offering, Nissha Medical Technologies Grounding (Diathermy) Pads are compatible with many electrosurgical generators.
Last Edited: 01.03.2024
Download Visit WebpageGrounding Pads - FR
From our patented TwinSafe design to our standard SwaroPlate offering, Nissha Medical Technologies Grounding (Diathermy) Pads are compatible with many electrosurgical generators.
Last Edited: 01.08.2023
Download Visit WebpageGrounding Pads - DE
From our patented TwinSafe design to our standard SwaroPlate offering, Nissha Medical Technologies Grounding (Diathermy) Pads are compatible with many electrosurgical generators.
Last Edited: 01.10.2022
Download Visit WebpageLas placas para electrocirugia - Spanish
Desde nuestro diseño patentado Twinsafe hasta nuestra oferta estándar de Swaroplate, las placas de NMT-HS son compatibles con muchos generadores electroquirúrgicos.
Last Edited: 01.07.2021
Download Visit Webpage