fully radiolucent patient monitoring kits
for use in Cardiology & Telemetry

CLARAVUE® is the best-in-class, hygienic solution for simple, accurate and fully radiolucent patient monitoring. With lightweight leadwires and a direct connection to the electrode sensor, CLARAVUE® helps to reduce artifacts during Stress tests.

For the past ten years, CLARAVUE® has been the prooven choice for superior trace quality and infection prevention in prominent european hospitals

Claravue Features

Disposable & Hygienic

Card image cap
Single Patient Use - Up to 5 Day Wear Time

Each completely disposable Patient Kit ensures the most hygienic solution for infection control.

Quality Trace

Card image cap
Pre-wired electrodes eliminate the need to snap leadwires onto electrodes.

CLARAVUE’S best-in-class electrodes reduce motion artifact associated with movement of the leadwires on electrode snaps. Repositionable, disposable patient kits can be used for up to 5-days.

Quick Patient Hookup


Patented quick connection point, repositionable and comfortable

CLARAVUE’S patented quick connection consolidates standard 10 leadwire ends to two simple, plug-style connections. Reduce opportunities for error by simplifying connections. Lightweight and conforming cables increase patient comfort.

 

CLARAVUE Packaging

CLARAVUE comes packaged in a dispenser case designed for easy storage and efficient product retrieval. Each patient kit is a single-use pack, containing all prewired electrodes.

 

Instructions For Use

Prep

Standard protocol for skin prep applies.

Open

Open the single CLARAVUE patient kit. Remove inner bag. Unwind sets from the holder card.

Peel

Gently remove electrode sets from release liner by peeling away from thumb tab.

Apply

Adhere the RA and RL electrode positions to the patient. Continue to apply set A across the patient’s chest to the LA position and down to the LL position. Repeat with set B, applying the V positions from left to right. CLARAVUE is repositionable, allowing the freedom to rearrange on the patient as necessary. Note: Gently pull the wire from the ribbon cable to expand the overall size of the set(s).

Insert

While holding the male end of the adapter (clear clip) attached to set A, align with the blue, triangular indicator. Press firmly until lever snaps. Repeat with the blue clip attached to set B.

5 Day Wear

Ensure a good signal is achieved on the monitor. If a standard three lead trace is necessary, unplug set B from the adapter cable and remove the corresponding V positions from the patient. CLARAVUE’s various lead configurations enables total hospital standardization.